TRID : 11714365 Actual Tender Number :
TEC

TEC TEC Combined Electrical works at various location in NITC
Combined Electrical works at various location in NITC, Combined Electrical works at various location in NITC, Supplying and laying 25mm x 3mm strip at 0.05 metre below ground as earth electrode, including connection/ terminating with SS nut,bolt,spring washer , double plate washer etc.as required ( jionting shall done by overlapping and with 2 set GI nut bolt and washer spaced 50mm), Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required, Triple pole, Supply and making end termination with brass compression gland and aluminium legs for 3.5 C x 70sq.mm (32 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required, Supply and laying of one number of 14 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required, Providing and fixing 125 A, 36 KA, FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections ,etc.as required, Supplying and fixing 40 A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying of one number 2C x 6 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required, 25A, 8 way (8 + 24), Double door, Supplying and drawing 3 x 4 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required, Supplying and fixing 63A rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) size on wall surface/pipe as required, Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required, Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, Supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x16 + 2x6sqmm of PVC insulated copper conductor, Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 300 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required, Health Centre, Supplying and fixing 32 A rating 4 pole , 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc.as required, Supplying and fixing 40 A rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc, as required, Supplying and fixing 4 module (125 mm X 75 mm) GI box alongwith modular base & cover plate for modular switches in recess etc. as required, supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required, Supplying and fixing 1/2 module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required, supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x10 + 2x6sqmm of PVC insulated copper conductor, Supplying and making end termination of suitable size for the submain wiring with suitable lugs for 4 x 16 + 2 x 6 sqmm of PVC insulated copper conductor, Supplying and fixing 32 A rating Triple pole , 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required, Single pole, Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), Providing and fixing 100 A , 4P MCCB, 16 KA breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing MCCB DB , making conection as required, Supplying and fixing 40A , three pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 6 pin 15/16 A modular socket ( 3 MD type ) on the existing modular plate & switch box including connections but excluding modular plate etc.as required, Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of three pole in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 63A rating, Four pole, Three phase, 415 Volts, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc as required, supplying and making end termination of suitable size for the submain wiring with Copper lugs for 4x16+ 2x6sqmm of PVC insulated copper conductor, Supplying and fixing 63A , Four pole, 430 V, C curve Miniature circuit breaker (MCB) in the existing MCB DB complete with connections, testing and commissioning etc. as required, Supplying and fixing 8 way Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar. interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator), Providing and fixing 25 mm X 6 mm G.I strip on surface or in recess for connections etc. as required, Supply of 4 x 50 Sq.mm PVC/ XLPE Aluminium Armoured Cabl at

Classified in :
Key Values
Tender Value : Refer Document
Contract Value : Refer Document
Difference : -
Key Date
Publication Date : 06-Oct-2025
Submission Date : -
Awarded Date : -
Completion Date : -
Key Location
Location : Kozhikode,Kerala,India
Address :
BidderList